Technical Parameters

Generator typeSilent Diesel Generator Sets
Rated power1100 kVA
Standby power1210 kVA
Engine brandYuchai
Engine modelYUC-11002
AlternatorMarathon
ControllerDeep Sea DSE8610
Voltage220/380V, 230/400V, 240/415V optional
Frequency50Hz standard, 60Hz optional
Fuel consumption231-275 L/h at 75% load
Noise level68-78 dB(A) at 7m
Dimensions3340 x 1268 x 1575 mm
Weight4200 kg
Fuel tank1320 L base tank or external tank optional
CoolingClosed water cooling with heavy-duty radiator
Certificate notesCE, ISO and market-specific documents can be checked during supplier review.

Typical Applications

This generator set can be reviewed for factories, farms, telecom towers. The final configuration should consider load type, start current, ambient temperature, sound requirement, fuel autonomy and installation location.

Installation Notes

Confirm foundation, airflow, exhaust direction, grounding, cable route and maintenance access before shipment. Indoor installations require careful radiator discharge and fresh air intake planning.

Maintenance and Spare Parts

Common service items include oil filter, fuel filter, air filter, belts, battery, coolant, sensors and controller-related accessories. Keep spare parts matched to engine model and serial number.

PDF Datasheet

A standardized PDF datasheet is available for buyer review. Final supplier datasheet, factory test report and certificate documents should still be confirmed before order.

Open PDF Datasheet

Dimension Drawing Notes

3340 x 1268 x 1575 mm
  • Overall reference size: 3340 x 1268 x 1575 mm.
  • Approximate operating weight: 4200 kg.
  • Confirm final base frame drawing, lifting point position and service clearance before production.
  • For indoor rooms, reserve maintenance access around the engine, alternator, radiator and control panel.

Controller Photo Checklist

For reviewed supplier records, the crawler and supplier follow-up should collect control panel and wiring photos. These photos help buyers check ATS, monitoring and alarm needs.

  • Deep Sea DSE8610 front panel photo
  • Controller wiring terminal photo
  • Main breaker and output terminal photo
  • Nameplate photo for generator, engine and alternator
  • Running test screen showing voltage, frequency and load

Engine and Alternator Brand Notes

  • Yuchai engine selection should be checked against local service access, fuel quality and required emissions documents.
  • Marathon alternator configuration should be confirmed with voltage, frequency, insulation class and protection needs.
  • Deep Sea DSE8610 control system should be matched with ATS, remote monitoring, alarm output and language requirements.

Optional Configurations

  • Weatherproof silent canopy with site noise target review
  • Automatic transfer switch integration
  • Battery charger and jacket water heater
  • External fuel tank or larger base tank
  • Remote monitoring and alarm output
  • Export packing with loading photos and test report
  • Parallel control cabinet and synchronization review

Recommended Spare Parts Package

  • Yuchai oil filter set
  • Yuchai fuel filter and water separator elements
  • Air filter element matched to intake system
  • Fan belt, radiator hose and clamps
  • Starting battery, battery cable and charger fuse
  • Deep Sea DSE8610 controller backup settings and wiring diagram
  • AVR, sensors and emergency stop switch for remote projects